26
Cisco CWDM Passive Optical System Installation Note
78-16565-02
Specifications
Table 6 CWDM OADM and Multiplexer/Demultiplexer Module Optical Specifications
Device Path Value
CWDM-MUX8A
Filter Passband Width Add/Drop ± 6.0 nm (minimum)
Channel Insertion Loss Add/Drop 2.2 dB (maximum)
Monitor Insertion Loss Network Tx/Rx
Monitor Tx/Rx
23 dB (maximum
CWDM-OADM4-x
Filter Passband Width Add/Drop ±6.0 nm (minimum)
CWDM Channel Insertion
Loss
Add/Drop 1.8 dB (maximum)
Pass 1550-nm Insertion
Loss
NETWORK Rx/Tx—PASS Tx/Rx 2.1 dB (maximum)
Pass 1310-nm Insertion
Loss
NETWORK Rx/Tx—PASS Tx/Rx 2.1 dB (maximum)
Monitor Insertion Loss NETWORK Rx/Tx—MONITOR Tx/Rx
PASS Rx/Tx—MONITOR Tx/Rx
23 dB (maximum)
CWDM-OADM1-xxxx
Filter Passband Width Add/Drop ±6.0-nm (minimum)
CWDM Channel Insertion
Loss
Add/Drop 1.5 dB (maximum)
Pass 1550-nm Insertion
Loss
NETWORK Rx WEST/EAST—
NETWORK Tx EAST/WEST
1.5 dB (maximum)
Pass 1310-nm Insertion
Loss
NETWORK Rx WEST/EAST—
NETWORK Tx EAST/WEST
1.7 dB (maximum)
Monitor Insertion Loss NETWORK Tx/Rx WEST/EAST—
TAP Tx/Rx WEST/EAST
23 dB (maximum)
WDM-1300-1550-S
Pass 1310-nm Insertion
Loss
Add/Drop 1.2 dB (maximum)
Pass 1550-nm Insertion
Loss
Add/Drop 0.8 dB (maximum)