After offloading the management of LACP from the VSM to the VEM, you must preserve the running
configuration in the startup configuration and reload the VSM before the offload takes effect. This
procedure has steps for doing this.
Know that offloading of LACP management to the VEMs is enabled by default on the VSM.
When you upgrade to 4.2(1)SV1(4) or before, the LACP offload management to the
VEMs is disabled by default. However, LACP offload is the only supportable mode
starting with release 5.2(1)SV3(1.1) and VEMs will automatically go into that mode
after you upgrade. We recommend that you add the LACP offload configuration to VSM
for consistency.
Note
Procedure
PurposeCommand or Action
Enters global configuration mode.switch# configure terminal
Step 1
(Optional)
Offloads LACP management from the VSM to the VEMs.
switch(config)# lacp offload
Step 2
If enabling LACP offload, a message displays to let you know
that a reload is required.
Offload of LACP management to the VEMs is enabled by default.
When you upgrade to 4.2(1)SV1(4) or before, the LACP
offload management to the VEMs is disabled by default.
However, LACP offload is the only supportable mode
starting with release 5.2(1)SV3(1.1) and VEMs will
automatically go into that mode after you upgrade. We
recommend that you add the LACP offload configuration
to VSM for consistency.
Note
(Optional)
Saves the change persistently through reboots and restarts by
copying the running configuration to the startup configuration.
switch(config)# copy
running-config
startup-config
Step 3
(Optional)
Displays the LACP offload status for verification.
switch(config)# show lacp
offload status
Step 4
The current status does not change to enabled until after
a reload.
Note
Reboots both the primary and secondary VSM.switch(config)# reload
Step 5
(Optional)
Displays the LACP offload status for verification.
switch(config)# show lacp
offload status
Step 6
The current status does not change to enabled until after
a reload.
Note
Cisco Nexus 1000V for VMware vSphere Interface Configuration Guide, Release 5.x
81
Configuring Port Channels
Configuring VEM Management of LACP

Table of Contents