If multichassis EtherChannel trunk (MCT) is enabled and the traffic flows from a virtual port channel
(vPC) peer link, the output displays Outgoing port id (vPC peer-link traffic).
To get accurate results, you must do the following:
(For unicast frames) Provide the destination MAC address (dst-mac) and the VLAN for hardware hashing
(vlan). When the destination MAC address is not provided, hardware hashing is assumed.
(For multicast frames) For IP multicast, provide either the destination IP address (dst-ip) or destination
MAC address (dst-mac) with the VLAN for hardware hashing (vlan). For non-ip multicast, provide the
destination MAC address with the VLAN for hardware hashing.
(For broadcast frames) Provide the destination MAC address (dst-mac) and the VLAN for hardware
hashing (vlan).
Examples
This example shows how to display the port channel load-balancing information:
switch# show port-channel load-balance
Port Channel Load-Balancing Configuration:
System: source-dest-ip
Port Channel Load-Balancing Addresses Used Per-Protocol:
Non-IP: source-dest-mac
IP: source-dest-ip source-dest-mac
switch#
The following table describes the fields shown in the display.
Table 4: show port-channel load-balance Field Descriptions
DescriptionField
The load-balancing method configured on the switch.System
The field that will be used to calculate the hash value
for non-IP traffic.
Non-IP
The fileds used for IPv4 and IPv6 traffic.IP
This example shows how to display the port channel load-balancing information when hardware hashing is
not used:
switch# show port-channel load-balance forwarding-path interface port-channel 5 vlan 3
dst-ip 192.168.2.37
Missing params will be substituted by 0's.
Load-balance Algorithm on FEX: source-dest-ip
crc8_hash: Not Used Outgoing port id: Ethernet133/1/3
Param(s) used to calculate load-balance (Unknown unicast, multicast and broadcas
t packets):
dst-mac: 0000.0000.0000
vlan id: 3
switch#