Send feedback to nx5000-docfeedback@cisco.com
1-13
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Advanced Fibre Channel Features and Concepts
Switch Interoperability
Hardware
cisco Nexus5020 Chassis ("40x10GE/Supervisor")
Intel(R) Celeron(R) M CPU with 2074100 kB of memory.
Processor Board ID FOX1009009B
bootflash: 987136 kB
switch kernel uptime is 0 days 20 hours 6 minute(s) 55 second(s)
Last reset
Reason: Unknown
System version:
Service:
Step 2 Verify if the interface states are as required by your configuration.
switch# show int brief
-------------------------------------------------------------------------------
Interface Vsan Admin Admin Status SFP Oper Oper Port
Mode Trunk Mode Speed Channel
Mode (Gbps)
-------------------------------------------------------------------------------
fc3/1 1 E on trunking swl TE 2 --
fc3/2 1 auto on sfpAbsent -- -- --
fc3/3 1 E on trunking swl TE 2 --
fc3/4 1 auto on sfpAbsent -- -- --
fc3/5 1 auto auto notConnected swl -- --
fc3/6 1 auto on sfpAbsent -- -- --
fc3/7 1 auto auto sfpAbsent -- -- --
fc3/8 1 auto auto sfpAbsent -- -- --
Step 3 Verify if you are running the desired configuration.
switch# show run
Building Configuration...
interface fc2/1
no shutdown
interface fc2/2
no shutdown
interface fc2/3
interface fc2/4
<snip>
interface mgmt0
ip address 6.1.1.96 255.255.255.0
switchport encap default
no shutdown
vsan database
vsan 1 interop
boot system bootflash:/nx5000-system-23e.bin
boot kickstart bootflash:/nx5000-kickstart-23e.bin
callhome
fcdomain domain 100 preferred vsan 1
ip route 6.1.1.0 255.255.255.0 6.1.1.1