PurposeCommand or Action
Suspends the selected VSAN.
vsan vsan-id suspend
Example:
switch(config-vsan-db)# vsan 23 suspend
Step 7
Negates the suspend command entered in the previous
step.
no vsan vsan-id suspend
Example:
switch(config-vsan-db)# no vsan 23 suspend
Step 8
Returns you to EXEC mode.end
Example:
switch(config-vsan-db)# end
Step 9
Interop Mode
Interoperability enables the products of multiple vendors to connect with each other. Fibre Channel standards
guide vendors to create common external Fibre Channel interfaces.
Related Topics
Switch Interoperability, on page 228
Displaying the Static VSAN Configuration
The following example shows how to display information about a specific VSAN:
switch# show vsan 100
The following example shows how to display VSAN usage:
switch# show vsan usage
4 vsan configured
configured vsans:1-4
vsans available for configuration:5-4093
The following example shows how to display all VSANs:
switch# show vsan
Default Settings for VSANs
The following table lists the default settings for all configured VSANs.
Table 17: Default VSAN Parameters
DefaultParameters
VSAN 1.Default VSAN
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)
128 OL-27583-01
Configuring and Managing VSANs
Displaying the Static VSAN Configuration