Power Requirements for Switch Components
To determine the power requirements of the Cisco Nexus 7000 Series switches, add the power requirements
of each of its components. For each component, multiply the number of its modules by its maximum or typical
power requirement. To find the quantities and power requirements for each Cisco Nexus 7000 Series switch,
see the following tables:
• Cisco Nexus 7004—see Table 15: Power Requirements for the Cisco Nexus 7004 Switch , on page 148
• Cisco Nexus 7009—see Table 16: Power Requirements for the Cisco Nexus 7009 Switch , on page 150
• Cisco Nexus 7010—see Table 17: Power Requirements for the Cisco Nexus 7010 System Components
, on page 152
• Cisco Nexus 7018—see Table 18: Power Requirements for the Cisco Nexus 7018 System Components,
on page 154
Table 15: Power Requirements for the Cisco Nexus 7004 Switch
TypicalMaximumQuantityComponent
——1 or 2 (same
type is using
2)
Supervisor Modules
109 WSupervisor 2 (N7K-SUP2)
147 WSupervisor 2 Enhanced (N7K-SUP2E)
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
148
Technical Specifications
Power Requirements for Switch Components