EasyManua.ls Logo

Cisco Nexus 7706 - Maximum Power Available for 3-kW AC Power Supplies

Cisco Nexus 7706
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TypicalMaximumQuantityComponent
1 to 4
(can
mix
types)
F2 I/O Modules
451 W500 W48-port 1- and 10-Gigabit Ethernet I/O module
(N77-F248XP-23E)
F3 I/O Modules
450 W
480 W48-port 1- and 10-Gigabit Ethernet I/O module (N77-F348XP-23)
650 W740 W24-port 40-Gigabit Ethernet I/O module (N77-F324FQ-25)
640 W730 W12-port 100-Gigabit Ethernet I/O module (N77-F312CK-26)
M3 I/O Modules
500 W
560 W48-port 1- and 10-Gigabit Ethernet I/O module
(N77-M348XP-23L)
700 W750 W24-port 40-Gigabit Ethernet I/O module (N77-M324FQ-25L)
800 W1095 W12-port 100-Gigabit Ethernet I/O module (N77-M312CQ-26L)
65
W
80 W3 to 6Fabric Modules (N77-C7706-FAB-2)
65
W
85 W3 to 6Fabric Modules (N77-C7706-FAB-3)
Fan Trays
30 W
300 W338 mm Gen 1 Fan Tray (N77-C7706-FAN)
30 W300 W376 mm Gen 2 Fan Tray (N77-C7706-FAN-2)
Maximum Power Available for 3-kW AC Power Supplies
The maximum power available for operations depends on the input power from your power source, the number
and output capabilities of your power supplies, and the power redundancy mode that you use. The following
table lists the amount of power available for 3-kW AC power supplies depending on power inputs, numbers
of power supplies, and the mode used.