EasyManua.ls Logo

Cisco Nexus 7706 - Power Supply LEDs

Cisco Nexus 7706
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Supply LEDs
Depending on the power supply (AC, DC and HVAC/HVDC power supplies), there are 1 or 2 input LEDs.
The Output, Fault, and ID LEDs have the same function for the AC, DC and HVAC/HVDC power supply
units.
StatusColorLED
The AC, HVAC/HVDC, or DC input voltage is within the valid range.GreenInput 1
The AC, HVAC/HVDC, or DC input voltage is outside the valid range.Off
The DC input voltage is within the valid range.
GreenInput 2
(available
only on DC
power
supply
units)
The DC input voltage is outside the valid range.Off
The AC or DC output power is within the valid range.
GreenOutput
The AC or DC output power is outside the valid range.Off
The AC or DC output voltage and power supply unit tests are okay.
OffFault
Self-diagnostic tests have failed or another power supply failure has occurred.Flasing red
The operator has activated this LED to identify this module in the chassis.
Flashing blueID
This module is not being identified.off