Before you begin
• Verify that the cable management frames are attached to the chassis.
• Verify that you have the following tools and equipment:
• Optional front door kit
• Door stop bracket
• Front door
• Number 1 manual Phillips torque screwdriver
Step 1 Attach the metal door-stop bracket to the top hood as follows:
a) Place the metal door bracket under the top hood of the cable management system and align with the two screws on
the metal bracket with two holes on the bottom of the top hood (see the following figure).
Figure 19: Attaching the Door Stop
Align the bracket screws to two screw holes in the
top hood
3Top hood1
Door stop bracket2
b) Secure the bracket to the hood by screwing in two captive screws on the bracket to the hood and tighten to each screw
to 8 in-lb (0.9 N·m) of torque.
Step 2 Attach the front door as follows:
a) Place the two rollers at the bottom of the front door on the two holders at the bottom of the right and left cable
management frames (see Callout 1 in the following figure).
Cisco Nexus 7706 Hardware Installation Guide
39OL-31330-01
Installing the Switch Chassis
Attaching the Front Door to the Chassis