Attach each interface cable to the appropriate port on the module. Use the label on each cable to determine
to which port each cable attaches.
Note
Installing or Replacing a Line-Card Expansion Module (LEM)
The switch can operate with one or more Line-card Expansion Modules (LEMs) installed in the chassis. If
there is at least one LEM installed and operating in the chassis, you can replace another LEM or install a new
LEM in an empty slot.
Limitation: N9K-X9400-16W has a limitation on link bring up for 10G/40G and 10G/100G when connecting
ports that are next to each other.
if port 1 is connected with 10G, and if 40G or 100G is connected in port2 then port 2 will be hw-disabled.
To recover port 2 from hw-disabled, you need to remove 10G from port 1 and you need to do OIR once on
port-2
Eth4/3 -- hwdisabled trunk full inherit QSFP-H40G-CU5M
Eth4/4 -- connected routed full 10G SFP-H10GB-AOC1M
ifav132-leaf18-sl# show int ethernet 4/3-4 status
Eth4/3 -- out-of-ser trunk full 40G QSFP-H40G-CU5M
Eth4/4 -- hwdisabled routed full inherit SFP-H10GB-AOC1M
ifav132-leaf18-sl# show int ethernet 6/7-8 status
------------------------------------------------------------------------------------------------
Port Name Status Vlan Duplex Speed Type
------------------------------------------------------------------------------------------------
Eth6/7 -- out-of-ser trunk full 10G 10Gbase-SR
Eth6/8 -- hwdisabled trunk full inherit QSFP-100G-CWDM4
ifav132-leaf18-sl# show int ethernet 6/7-8 status
------------------------------------------------------------------------------------------------
Port Name Status Vlan Duplex Speed Type
------------------------------------------------------------------------------------------------
Eth6/7 -- hwdisabled trunk full inherit 10Gbase-SR
Eth6/8 -- out-of-ser trunk full 100G QSFP-100G-CWDM4
Note
Once a LEM is removed, you must wait at least 10 seconds before you insert a new one. Once the LEM is
inserted, the retimer init program will be started in MIFPGA. Any removal or disturbance would cause
retimer cannot access LEM MIFPGA and a crash can happen.
Caution
Statement 1034—Backplane Voltage
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when
servicing.
Warning
Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide
34
Replacing Modules
Installing or Replacing a Line-Card Expansion Module (LEM)