EasyManua.ls Logo

Cisco ONS 15454 M6 - Page 141

Cisco ONS 15454 M6
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
a) Plug one connector into Port 1 of the working Catalyst 3560.
b) Plug the other connector into any one of the MSM ports that correspond to the TNC/TNCE/TSC/TSCE
card in Slot 1 of the node controller.
Step 2 Using a cross-over (CAT-5) LAN cable:
a) Plug one connector into Port 1 of the protect Catalyst 3560.
b) Plug the other connector into any one of the MSM ports that correspond to the TNC/TNCE/TSC/TSCE
card in Slot 8 of the node controller.
Step 3 Using a cross-over (CAT-5) LAN cable:
a) Plug one connector into Port 23 of the working Catalyst 3560.
b) Plug the other end into Port 23 of the protect Catalyst 3560.
Step 4 To connect an ONS 15454 M6 subtending shelf to the Catalyst 3560 switches, complete the following:
a) Using a cross-over (CAT-5) LAN cable:
Plug one connector into the MSM port of the subtending ONS 15454 M6 shelf that corresponds
to the TNC/TNCE/TSC/TSCE card in Slot 1.
Plug the other end into Port 2 of the active Catalyst 3560.
b) Using a cross-over (CAT-5) LAN cable:
Plug one connector into the MSM port of the subtending ONS 15454 M6 shelf that corresponds
to the TNC/TNCE/TSC/TSCE card in Slot 8.
Plug the other end into Port 2 of the standby Catalyst 3560.
c) Repeat Step 4a and Step 4b for each subtending shelf in the multishelf configuration using Port 3 to Port
20 on the Catalyst 3560 switches.
Step 5 To connect an ONS 15454 subtending shelf to the Catalyst 3560 switches, complete the following:
a) Using a cross-over (CAT-5) LAN cable:
Plug one connector into the front panel of the subtending shelf TCC2/TCC2P/TCC3 card in
Slot 7.
Plug the other end into Port 2 of the active Catalyst 3560.
b) Using a cross-over (CAT-5) LAN cable:
Plug one connector into the front panel of the subtending shelf TCC2/TCC2P/TCC3 card in
Slot 11.
Plug the other end into Port 2 of the standby Catalyst 3560.
c) Repeat Step 5a and 5b for each subtending shelf in the multishelf configuration using Port 3 to Port 20
on the Catalyst 3560 switches.
Step 6 To daisy chain up to six Catalyst 3560 switches, use a cross-over (CAT-5) LAN cable to connect Port 21 of
switch 1 to Port 21 of switch 3 and Port 21 of switch 2 to Port 21 of switch 4. Use another cross-over (CAT-5)
LAN cable to connect Port 22 of switch 3 to Port 22 of switch 5 and Port 22 of switch 4 to Port 22 of switch
6.
Installing the ONS 15454 M6 Shelf
141
Installing the ONS 15454 M6 Shelf
DLP-G682 Connect the ONS 15454 M6 as the Node Controller in a Mixed Multishelf Configuration Using the Catalyst 3560

Table of Contents

Related product manuals