Step 2 Verify that the DC power module is installed in Slot A or Slot B (or both slots) of the ONS 15454 M6.
Step 3 Unscrew the screws to a torque value of 4 in-lb (0.45 N-m) to remove the protective covers from the DSUB
power connector of the DC power modules (see the following figure).
Figure 259: Connecting Office PowerDC Power Modules (ETSI Only)
Step 4 Attach the DC ETSI power cable to the cable connector in the DC power module (see the following figure).
Step 5 Tighten the screws to a torque value of 4 in-lb (0.45 N-m) to secure the cable (see the following figure).
Cisco ONS 15454 Hardware Installation Guide
383
Installing the ONS 15454 M6 Shelf
DLP-G573 Connect Office Power (DC) to the ONS 15454 M6 Shelf (ETSI Only)