4-14
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 4 Error Messages
EID-2200 CTC has detected a jar file deletion. The jar file was used to
manage one or more nodes. This CTC session will not be able
to manage those nodes and they will appear gray on the network
map. It is recommended that you exit this CTC session and start
a new one.
Refer to the error message text.
EID-2202 An intra-node DRI circuit must have two sources. Intranode circuit must have two sources to
be a dual ring interconnect (DRI).
EID-2203 No member was selected. You must select a member.
EID-2204 The number of circuits must be a positive integer. The number of circuits cannot be zero or
negative.
EID-2205 The circuit type must be selected. You must select a circuit type.
EID-2206 The profile cannot be autoselected. Please select profile(s) to
store and try again.
Refer to the error message text.
EID-2207 You cannot add this span. Either the ring name is too long (that
is, ring name length is greater than {0}) or the endpoints do not
support alphanumeric IDs.
Reduce the length of the ring name, or
remove the alphanumeric characters from
the end points.
EID-2208 This is an invalid or unsupported JRE. The version of Java Runtime Environment
(JRE) is either invalid or unsupported.
EID-2209 The user name must be at least {0} characters long. The user name must be at least of the
specified character length.
EID-2210 No package name was selected. You must select a package name.
EID-2211 No node was selected for upgrade. You must select a node for the upgrade.
EID-2212 A protected line is not provisionable. The protected line cannot be provisioned.
Choose another line.
WID-2213 The current type or state of some drops does not allow the new
circuit state of {0} to be applied to them indirectly.
The circuit state, specified by {0} cannot be
applied to the selected drops.
EID-2214 The node is disconnected. Please wait until the node
reconnects.
Refer to the error message text.
EID-2215 An error occurred while leaving the {0} page. There was an error while leaving the
specified page.
EID-2216 An error occurred while entering the {0} page. There was an error while entering the
specified page.
EID-2217 Some conditions could not be retrieved from the network view Refer to the error message text.
EID-2218 The bandwidth must be between {0} and {1} percent. The bandwidth must be within the specified
parameters.
EID-2219 The protection operation failed. An XC loopback was applied
on the cross-connection.
As the protection operation failed, a
cross-connect (XC) loopback will be
applied on cross-connection.
EID-2220 The tunnel status is PARTIAL. CTC is not able to change it.
Please try again later.
Refer to the error message text.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description