Chapter 3 Printer Adjustments
Chapter 3
Printer Adjustments
Installing the Media (p.22)
Sensor Adjustments
The sensing level of both the transparent (see thru) and reective sensors
is adjusted separately and independently. Firstly, the sensor type must
be selected using the Sensor Method Selection shown below. Then the
adjustment and calibration of the sensor can be made.
Entering Sensor Adjustment Mode
1. Turn on the power while pushing the PAUSE key, FEED key,
and STOP key simultaneously.
PAUSE
FEED
STOP
Power Switch
2. After “Sensor Cal Mode lights up, release the keys to change
the printer to sensor adjustment setting mode.
Sensor Cal Mode
See Through
Sensor Selection Method (Transparent
Reective)
To switch from transparent to reective sensor, hold down the MENU
key and then press the STOP key. Each time you press the STOP key, you
switch to back and forth between the two sensor types.
If the transparent sensor is selected, “See Through is displayed and
the buzzer sounds once. If the reective sensor is selected, “Reect” is
displayed and the buzzer sounds twice.
Sensor Cal Mode
See Through
Hold Press/Release
MENU
STOP