[0-Position Correction]
0-Position Correction of Function Hand and Date Wheel:
1. Pull the crown out to Position 1 in the chronograph [CHR] mode to correct the
function hand and date wheel.
2. Click (turn) the crown to the left to align the date wheel.
(1) Clicking the crown once causes the function hand to make four revolutions
and the date to be corrected by one day.
(2) Turning the crown rapidly (clicking continuously two or more times) causes
the function hand to advance continuously. When stopping the function
hand, click the crown once to the right or left. When the function hand is
not stopped manually, it stops automatically after advancing 31 days.
The 12:00 position immediately after the date changes to the “1st” is the 0 posi-
tion of the function hand. After correcting the date wheel to the “31st” by turn-
ing the crown, press button (A) to finely correct the function hand so that the
function hand is aligned at the 0 position after the date wheel changes to the
“1st”.
0-Position Correction of 24 Hour Hand, Hour Hand, Minute Hand and Sec-
ond Hand:
1. Pull the crown out to Position 2 in the chronograph [CHR] mode to correct
each hand.
2. Pressing button (A) causes the second hand to be corrected by one second at a
time each time it is pressed. Continuously pressing button (A) causes the sec-
ond hand to advanced rapidly.
3. Clicking the crown allows correction of the 24 hour hand, hour hand and
minute hand.
(1) Clicking the crown once to the right causes the hour and minute hands to
move clockwise.
(2) Clicking the crown once to the left causes the hour and minute hands to
move counter-clockwise.
Turning the crown rapidly (clicking continuously two or more times) causes
the hands to advanced rapidly. When stopping the hands, click the crown
once to the right or left. When the hands are not stopped manually, they stop
automatically after being corrected by 12 hours.