* POWER SUPPLY English
CITIZEN model SDC-382II is a dual-powered (high power solar + back-up
battery) calculator operative under any lighting conditions.
-Auto power-off function-
The calculator switches the power off automatically if there has been no
key entry for about 9 minutes.
-Battery change-
If the back-up battery needs to be changed, open the lower cabinet to
remove the old battery and insert a new battery in the indicated polarity.
After changing battery, please use a metal, elliptical object to press the
RESET pad on printed circuit board.
* KEY INDEX English
[
ON
CE C
] : Power on / Clear Entry / Clear key
[00
→
0] : Right Shift key [M+] : Memory plus key
[M–] : Memory minus key [+/–] : ±Sign change key
[MR] : Memory recall key [MC] : Memory clear key
[MU] : Mark-up / Mark-down key [GT] : Grand total key
[
] : Square root key [RATE] : Tax rate setting key
[
STORE
+TAX
] : ➀ Price with Tax key
➁ To store tax rate when pressing [RATE] and [+TAX] keys.
[
RE CAL L
-TAX
] : ➀ Price without Tax key
➁ To recall tax rate when pressing [RATE] and [-TAX] keys.
A
0 2 3
F
Decimal place selection switch
– F –
– 0 – 2 – 3 –
– A –
Floating decimal mode
Fixed decimal mode
ADD–mode automatically enters the monetary decimal in
addition and subtraction calculations
5/4
Round up / Round-off / Round-down switch
The Signs Of The Display Mean The Following:
M : Memory TAX : Amount of tax
– : Minus (or negative) –TAX : Price excluding tax
E : Overflow-error +TAX : Price including tax
GT : Grand total RATE : Tax rate setting
% : Tax rate stored
* OPERATION EXAMPLES English
1.Calculation Examples
Before performing each calculation, press the [
ON
CE C
] key two times.
Example Key operation Display
2 x 3 = 6
2 [x] 2 [
ON
CE C
] 3 [=]
GT 6.
7 x 9 = 63 7 [÷] [x] 9 [=]
GT
63.
300 x 27% = 81 300 [x] 27 [%]
GT
81.
56
11.2
x 100% = 20%
11.2 [÷] 56 [%] GT
20.
300+(300 x 40%)=420 300 [+] 40 [%]
GT
420.
300–(300 x 40%)=180 300 [–] 40 [%]
GT
180.
1400 x 12% = 168 1400 [x] 12 [%]
GT
168.
6 + 4 + 7.5 = 17.5 6 [+] 4 [+] 7.5 [=]
GT
17.5
5 x 3 ÷ 0.2 = 75
[
ON
CE C
] 5 [x] 3 [÷] 0.2 [=]
GT
75.
8 ÷ 4 x 3.7 + 9 =16.4 8 [÷] 4 [x] 3.7 [+] 9 [=]
GT
16.4
5
4
= 625 5 [x] [=] [=] [=]
GT
625.
1 / 2 = 0.5 2 [÷] [=]
GT
0.5
10) 3 x (2
1
+
= 0.0625
2 [x] 3 [+] 10 [÷] [=]
GT
0.0625
A
0 2 3 F
144
= 12
144 [
]
12.
A
0 2 3 F
5/4
$14.90+$0.35–$1.45+
$12.05=$25.85
1490 [+] 35 [–] 145
[+] 1205 [=] GT
145.
25.85
2.Memory Calculation
[MC] [
ON
CE C
] 0.
12 [x] 4 [M+] 20 [÷] 2 [M–]
M
10.
[MR]
M
38.
A
0 2 3 F
5/4
(12 x 4) – (20 ÷ 2)
= 38
[MC] [
ON
CE C
]
0.
3.Constant Calculation
2 + 3 = 5 2 [+] 3 [=] 5.
4 + 3
= 7 4 [=] 7.
3 x
4 = 12 3 [x] 4 [=] 12.
A
0 2 3 F
3 x 6 = 18 6 [=] 18.
4.Overflow Error Clear
123456789012
123’456’789’012.
[x] 100000 [00
→
0] 10000.
[=] E 1’234.56789012
123456789012 x 10000
= 1'234.56789012 x 10
12
[
ON
CE C
]
0.
5.Price Mark-Up & Down Calculation
2000+(P x 20%)=P
P=
20% - 1
2000
=2'500.00
2500–2000 = 500.00
2000 [÷] 20 [MU]
[MU]
2'500.00
500.00
2000–(P x 20%)=P
P=
20% 1
2000
+
=1'666.66
2000 [÷] 20 [+/–] [MU]
1'666.66
A
0 2 3 F
5/4
15000
15000 - 18000
x100%
= 20.00%
18000 [–] 15000 [MU] 20.00
6.GT-MEMORY
Pressing [GT] twice before you operate GT function.
20 + 10 = 30 [GT] [GT] 20 [+] 10 [=] GT 30.
45 – 25 = 20 45 [–] 25 [=] GT 20.
50 x 3 = 150 50 [x] 3 [=] GT 150.
total = 200 [GT] GT 200.
200 x 15% = 30 [x] 15 [%] GT 30.
200 + (200 x 15%) = [GT] GT 230.
230 [GT] 230.
A
0 2 3 F
[
ON
CE C
] 0.
All calculation results are automatically accumulated in GT.
7.Tax Calculation
100+TAX(3%) = 103
Ta x s u m = 3
3 [RATE] [+TAX]
100 [+TAX]
[+TAX]
3.
103.
3.
%
+TAX
TAX
A
0 2 3 F
5/4
3 = Tax sum 103 = Tax inclusive value
206-TAX(3%) = 200
Ta x s u m = 6
[
ON
CE C
] [RATE] [-TAX]
206 [-TAX]
[-TAX]
3.
200.
6.
%
-TAX
TAX
6 = Tax sum 200 = Tax exclusive value