193
BRAKES
DRAINING, FILLING AND BLEEDING THE BRAKING SYSTEM
Using the bleeding apparatus.
Connect the bleeding apparatus [1] on the brake fluid reservoir (4).
Adjust the apparatus pressure to 2 bars.
For each brake circuit:
- Connect a transparent tube onto the bleed screw.
- Submerge the other end of the tube in a clean container.
- Open the bleed screw.
- Wait until the fluid is flowing out without air bubbles.
- Close the bleed screw.
- Remove the bleeding apparatus.
- Check the brake fluid level (should be between «DANGER» level and «MAXI» level).
- Fill if necessary with the approved and recommended synthetic brake fluid.
Without bleeding apparatus.
NOTE: Two operators are necessary.
For each brake circuit:
- Apply the brake pedal to place the circuit under pressure.
- Connect a transparent tube onto the bleed screw.
- Submerge the other end of the tube in a clean container.
- Open the bleed screw.
- Wait until the fluid is flowing out without air bubbles.
- Close the bleed screw.
NOTE: Recommence the process a second time if that is necessary.
- Check the brake fluid level (should be between «DANGER» level and «MAXI» level).
- Fill if necessary with the approved and recommended synthetic brake fluid.