2.3. Connecting the Communication Cable
Follow the procedure below to connect the special CC-Link cable to the module.
(1) Peel the sheath of the cable off without causing a broken wire (length of peeled cable sheath:
7mm). Do not solder the bare cable. Otherwise poor continuity may be caused. The solderless
terminals specified below are recommended. Note that the peeling size of the cable sheath
varies according to the type of the solderless terminal (see the figures below).
Fig. 2.4 Peeling size of communication cable
(2) Insert the DA (blue), DB (white), DG (yellow) and SLD (bare) cables of the CC-Link cable into
the corresponding holes while taking care of the orientation of the accessory connection
connector (BLZ5.08/5FAU) (see the figure below), and tighten the cable fixing screw.
The recommended connector is BLZ5.08/FAU manufactured by Weidmüller.
Fig. 2.5 Connection example of communication cable
(3) After checking that the cable name is the same as the one indicated on the module, insert the
connection connector into the module and securely tighten the connector fixing screw to a
tightening torque of 0.3N·m.
If solderless terminals are not used
About 50mm
If solderless terminals are used
To insert a single cable
not twist)
Wire 0.5mm
2
(Do not twist)
Part name: Sleeve with
insulating cover
Model: H0.5/12
Manufacturer: Nihon
Weidmüller
Special tool for solderless terminal
Part name: Crimper
Model: PZ1.5 or PZ4
Manufacturer: Nihon Weidmüller
Part name: Sleeve with
insulating cover
Model: H0.5/15
Manufacturer: Nihon
Weidmüller
Special tool for solderless terminal
Part name: Crimper
Model: PZ1.5 or PZ4
Manufacturer: Nihon Weidmüller
(White)
(Yellow)
(Bare)