3. CC-Link Communication Function
[SMF-2008-A]
ā 3-1 ā
3. CC-Link Communication Function
3.1. Communication Specifications
Table 3.1. Communication specifications
Supply 5V DC from the servo amplifier.
Number of stations
2 (remote device station)
Number of remote input
48
Number of remote output
48
8 input words, 8 output words
Communication speed 10M/5M/2.5M/625k/156kbps
(Selected with a parameter setting)
Frame synchronization method
Bus type (compliant with EIA RS-485)
Connection cable Cable compatible with CC-Link Ver. 1.10
(3-conductor twisted pair cable with shield)
1 to 63 (parameter setting)
Number of connected
Max. 32 remote device stations, 2 stations