GB
19
The air-blast nozzle (4) protects panes of glass,
for example, from being heated up by diverting
the air current.
The reducing nozzle (5) produces a precise air
current which can be used for deforming synthetic
materials, for example.
The reflector nozzle (6) produces a flat air current
which can be used for thawing frozen water pipes,
for example.
Check before switching on!
Check the safe condition of the product:
Check that the air inlet openings are not blocked.
Check all parts to make sure that they fit tightly.
Check whether there are any visible defects: bro-
ken parts, cracks, etc.
Switching on/off
Attach the required cap nozzle.
Connect the product to the power supply.
Point the nozzle at the surface to be treated.
Switching on: Set the On/Off switch (3) to posi-
tion [I][II].
Switching off: Set the On/Off switch (3) to posi-
tion [0].
As soon as the work is completed pull out the
mains plug and put the product on its stand (4) to
let it cool down ( P. 4, item 3).
Cleaning and maintenance
Cleaning the product
Careful handling and regular cleaning ensure that the
product remains functional and efficient for a long
time.
Wipe down the product with a slightly damp cloth.
Never spray the product with water or expose it to
water.
Never use detergents or solvents for cleaning.
This can cause irreparable damage to the prod-
uct. The plastic parts can be eaten away by the
chemicals.
Keep the air inlet openings and nozzle clear of
impurities and blockages.
Storage and transport
Storage
Allow the product to cool off completely before
storing.
Store the product in a dry place.
Transport
Use the original packaging to ship whenever pos-
sible.
Troubleshooting
If something isn’t working…
Malfunctions are often caused by minor faults. You
can easily remedy most of these yourself. Please
consult the following table before contacting the ven-
dor. You will save yourself a lot of trouble and possibly
money too.
If you can’t fix the fault yourself, contact your nearest
vendor. Please be aware that any improper repairs
will also invalidate the warranty and additional costs
may be incurred.
DANGER! Risk of injury! The product
must only be put into operation if no defects
are found. It is crucial that any defective
parts are replaced before the product is
used again.
NOTICE! Risk of product damage!
Always maintain a minimum distance of
25 mm between the nozzle and the surface
to be treated.
NOTICE! Risk of product damage! Never
use the product with the air inlet openings
pointing downwards. Dirty air can be sucked
in.
NOTICE! Risk of product damage! The
product must always be used with one of the
cap nozzles.
DANGER! Risk of injury!
DANGER! Risk of injury! Switch off the
product and disconnect the mains plug
before all cleaning and maintenance work.
Wait until all moving parts have come to a
complete stop and the product has cooled
down.
DANGER! Risk of injury! Make sure that
unauthorized persons do not have access to
the product!
DANGER! Risk of injury! Improper repairs
can result in the product functioning
unsafely. This endangers yourself and your
environment.
Fault/malfunction Cause Remedy
Product not running. No mains voltage? Check cable, plug, socket and fuse.
Cable faulty? Have it replaced by a qualified elec-
trician.
Product heats up without air
current.
Casing faulty. Disconnect the product from its
power supply. Do not use it again.