EQUIPMENT MANUAL 251-16-1
251/251-16-1
Page 5
ISOLATION BETWEEN
CHANNELS: 60 dB, minimum.
OUTPUT NOISE: Greater than 75 dB below rated, all outputs.
POWER SUPPLY: 28 VDC, 5 ampere maximum.
OPERATING TEMPERATURE: From -55 to +70°C. Thermal fold back of the speaker
outputs occurs if the heatsink temperature reaches 105°C.
OPERATING ALTITUDE: To 70,000 feet.
QUALIFIED TO:
FAR PART 21, TSO-C50c [A2F2]-BA(CL)XXXXXXZ(BZ)AAATZ(XXC2)XX
RTCA DO-160C: Refer to Table 3, Environmental Qualification Form,
for test category information.