Cobra C6 - Gas Specifications

Cobra C6
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at the ‘High’
setting. Operating pressure is ex-factory set through appliance regulator and is not to be adjusted,
apart from when carrying out gas conversion. (Refer to ‘Gas Conversion’ section for details).
Burner Injector
Ø 2.10mm Ø 1.25mm
Open Burner
Low Fire Setting
¾ turn open c.c.w. ¼ turn open c.c.w.
Burner Aeration Setting
16mm open. 16mm open.
Pilot Injector
0.30mm 0.20mm.
Griddle
Burner Injector
Ø 2.00mm Ø 1.25mm
Low Fire Setting
5
/
8
turn open c.c.w.
3
/
8
turn open c.c.w.
Burner Aeration Setting
Fully open. Fully open.
Pilot Injector
0.35 0.23
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa 2.6 kPa
Gas Regulator Cap Screw