9.
7. Programming.
1. Programming automatic controls for manual water filling.
1.1. Fill the water to A in the tank up to the long sensor pin.
See fig. 1. Approximately 4 litres.
1.2. Keep button (B) pressed and switch on the machine
with the switch (D) at the same time.
A
fig.1.
fig.2.
B
C
D
1.3. The display shows T1
Change the type of machine with buttons B or C.
1.4. T1 = HVA automat
T2 = HVM manual
1.5. Confirm the choice by holding down the buttons (B) and (C) at the same time
for approximately 5 seconds.
NOTE Install the plug supplied in the inlet valve (E) to avoid possible leakage.
E