EasyManua.ls Logo

Cointra CAMI 6 - Technical Data Table

Cointra CAMI 6
90 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
69
cod. 3542C100 - Rev. 01 - 09/2022
CAMI
4.4 Technical data table
Data
Units
CAMI 6 CAMI 11
Product identication codes G20
GCA1HFKF GCA1MFKF
Product identication codes G31
GCA1HGKF GCA1MGKF
Countries of destination
ES - PT - IT - FR - BE
Gas category
II2H3+ (ES-PT-GB) / II2HM3+ (IT) / II2E+3+ (FR) / I2E+ (BE) / I3+ (BE)
Maximum heat capacity
kW 11.8 21.1 Q
Minimum heat capacity
kW 6.3 8.1 Q
Maximum heat capacity
kW 10.4 18.9
Minimum heat capacity
kW 5.4 7.0
Performance at max. power
% 87 87
Burner injectors G20
n. x Ø 14 x 0.82 24 x 0.85
Gas supply pressure G20
mbar 20 20
Maximum gas delivery G20
m3/h 1.25 2.23
Minimum gas delivery G20
m3/h 0.67 0.86
Burner injectors G230
n. x Ø 14 x 0.95 24 x 0.95
Gas supply pressure G230
mbar 20 20
Maximum gas delivery G230
m3/h 0.97 1.73
Minimum gas delivery G230
m3/h 0.52 0.66
Burner injectors G31/G30
n. x Ø 8 x 0,49 / 6 x 0,47 18 x 0.49 / 6 x 0.47
Gas supply pressure G31/G30
mbar 37 / 29 37 / 29
Max. gas delivery G31/G30
m3/h 0.92 1.64
Min. gas delivery G31/G30
m3/h 0.49 0.63
NOx emission class
- 6 (<56 mg/kWh) NOx
Max. operating pressure
bar 10 10 PMS
Min. operating pressure
bar 0.2 0.2
DHW delivery ∆25º
l/min 6.0 10.8
DHW delivery ∆30º
l/min 5.0 9
Degree of protection
IP X4D
Supply voltage
V/Hz 3V =
Absorbed electrical power
W / /
Empty weight
Kg 8.5 9.50
Type of unit
B11BS

Table of Contents

Related product manuals