EasyManua.ls Logo

COMDYNA GP-6 - Page 12

Default Icon
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATOR'S
&
MAINTENANCE
MANUAL
page
10.
SYMBOL
COLOBCODE
DESCRIPTION
SJ'
Gray
Alternate
summing
junction
for
amplifiers
1 -
4.
(Conducting
when
a
logic
11
0
11
is
patched
to
the
SW
switch
control
jack.)
1,-¥-
Green
Standard
input
summing
resistor,
normalized
as
a
unity
value
to
sim-
plify
programming.
(Actual
resistance
is
SOK
ohms.)
.1
rY-
Green
Summing
resistor
input
one
tenth
the
standard
value.
(Actual
resis-
tance
is
5K
ohms.)
·U,
B
Green
One
end
of
standard
integrating
capacitor,
normalized
so
that
the
11
1
11
resistor
and
B
capacitor
combine
to
produce
a
one
second
time
con-
stant,
as
referred
to
programming
time
scales.
(Actual
capaci-
tance
is
20
ufd
for
the
slow
and
.05
ufd
for
the
fast
time
scales.
·0,.18
Green
Integrating
capacitor
that
has
a
value
one
tenth
the
standard
B
capac-
itor.
(Actual
capacitance
is
2
ufd
for
the
slow
and
.005
ufd
for
the
fast
time
scales.)
SJ~C
Green
Resistor
network
for
the
SJ'
summing
junction.
Amplifier
becomes
an
0 0
inverter
when
SJ'
is
conducting.
Normally
used
for
integrator
initial
2
conditions.
May
also
be
used
as
the
feedback
and
input
with
the
SJ
summing
netwokr.
(See
Summer
patching.)
i
Yellow
Attenuator:
bottom
end
grounded;
top
end
input
and
wiper
output
brought
out
to
the
panel
--
wiper
indicated
by
the
arrow.
-
.
i
Yellow
Voltage
divider:
top
and
bottom
end
inputs
and
wiper
brought
out
to
the
panel
--
wiper
indicated
by
the
arrow.
:c
Black
System
ground.
11!'
~
Multiplier
network
symbol.
X
Brown
One
of
two
multiplier
inputs.
y
Brown
One
of
two
multiplier
inputs.
'L
Gray
Multiplier
output,
a
current
proportional
to
the
product
of
11
X
11
and
11
Y/
normalized
so
that
when
connected
to
the
summing
junction
of
an
op-
erational
amplifier
with
a
11
1
11
resistor
feedback,
and
with
reference
patched
as
both
inputs,
the
amplifier
output
equals
reference.
SW
White
Electronic
switch
'control.
Logic
O
(ground
or
positive
voltage,)
SJ'
con-
ducts,
SJ
shuts
off.
Logic
1
(-5V
or
less,)
SJ
conducts
and
SJ'
shuts
off.
Hold
logic
(-2V
thru
-3V)
SJ'
shuts
off
and
the
summer
resistor
network
is
disconnected
electronically
from
the
amplifier/capacitor
feedback.
OP
White
Computer's
operate
bus,
integrator
mode
logic
from
the
central
aper-
push
button
control,
patched
to
11
SW'
for
normal
integrator
operation.
COMDYNA,
INC.