EasyManua.ls Logo

Comet MTP MC 8 - Power Supply Connection (Electric Motor); Power Supply Connection Warning

Comet MTP MC 8
84 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
•Havea
Skilled Technician
performtheinspectionsrequiredbyspecialmaintenance.
•Wearclothingandpersonalprotectiveequipmentabletoprovideadequateprotectionfromanyhigh-pressure
jetsandchemicalproductsused.
Carry out the preliminary activities indicated in the manual of the machine in which the motor pump
is integrated and in that of any combustion engine tted; unless otherwise indicated, with respect to the
motor pump, always remember the following.
a)Withtheengineoandthemotorpumpcompletelycooleddown,checktheoillevelcorrespondstothe
referencemarkonthepositive-displacementcompensator(6),oronthespecicoillevelindicator(MTPP48
andMTPYA65).
Foranytouchups,refertothetypesoflubricantsindicatedintheparagraph
“specIfIcatIons and technIcal
data
.
WARNING
•InthecaseoftheMTPP48motorpumps,a
Skilled Technician
willhavetobecontactedforanyoiltop-ups
becausetheoilllingcapisnotdirectlyaccessible.
b)
Ifpresent,checkthecorrectinationofthepressureaccumulatorbymeansofanormalcompressed-airgun
withpressuregaugeofthetypeofthoseusedtochecktyreinationpressure.
Inationdependsonthepressurerangewithinwhichthemotorpumpwillbeoperating,accordingtothe
indications of the following table:
OPERATING PRESSURE ACCUMULATOR INFLATION PRESSURE
bar psi bar psi
2-5 29-73 2 29
5-10 73-145 2-5 29-73
10-20 145-290 5-7 72-102
20-50 290-725 7 102
CAUTION
•Incaseofoperationatverylowtemperatures,makesurethereisnoiceinsidethemotorpumpandpipes.
•Performthechecksrequiredbyroutinemaintenance,withspecialreferencetothoserelatingtotheoil.
CHECKING AND CONNECTING UP TO THE POWER SUPPLY
MOTOR PUMPS WITH ELECTRIC MOTOR
WARNING
•Alsofollowtheinstructionscontainedinthemanualofthemachineinwhichthemotorpump is
integrated.
•A
Skilled Technician
must:
-makesurethepowersupplyofthemotorpumpfeaturesasuitablefuseandisinconformitywiththedetails
shownontheplate(12):inparticular,thepowervoltagemustnotbeoutsidethe±5%range;
-connectaplugincompliancewiththelawsapplicableinthecountrywherethemachineinwhichthemotor
pumpisintegratedisinstalled,inthecaseofthepowerleadbeingwithoutsuchplugandofthemotorpump
notbeingpermanentlyconnectedtoapowersupplysource.
•econnectiontothepowersourcemustbemadebya
Skilled Technician
andmustbeincompliancewith
therequirementsofIEC60364-1.
epowersupplylineofthemotorpumpmustbettedwithaswitchabletointerruptthepowersupply
whenevergrounddispersionexceeds30mAfor30msorwithadevicefortestingtheearthcircuit.
•Ifthemotorpumpdoesnothaveapowerleadandplug,oranotherdevicefordisconnectingitfromthemains,

Related product manuals