33
paragraph, meaning
withoutanymovingparts,nopipefullofliquidunderpressureandonlyaer
complete cooling.
Inparticular,alwaysremembertodisconnectthepowersupplyordisconnectthesparkplugcontact.
•Anymaintenancejobsmustbeperformedinconditionsoftotalstability.
•
WARNING.
Toensurethesafetyofthemotorpump,onlyuseoriginalsparepartssuppliedbytheManufacturer
orapprovedbyit.
ROUTINE MAINTENANCE
Perform the routine maintenance jobs shown in the manual of the machine in which the motor pump is
integrated and in that of any combustion engine equipping the machine; unless otherwise indicated, in
relation to the motor pump, remember the following.
MAINTENANCE SCHEDULE JOB
After every use •Checkpumpoilaccordingtoinstructionsin
“prelImInary actIvItIes”
paragraph.
•Checkandifnecessarycleanthesuctionlter.
•Checkanypowercable,high-pressurepipes,clamptightnessandcorrecttting
ofhooks(8).
In the event of one or more parts being damaged, do not use the machine and
contact a
Skilled Technician
.
Every 50 hours •Oilandgreasetherotatingorslidingpartsaccessibletotheoperator.
•Checktheinationpressureoftheaccumulator(9)(ifany).
•Checktheintegrityofthesuctioncircuit.
•Checkthefasteningofthemotorpumptothestructureofthemachineinwhich
it is integrated.
In the event of such fastening being precarious, do not use the machine and
contact a
Skilled Technician
(1)
.
(1)Checksmustbemademorefrequentlyifthemotorpumpoperateswheretherearestrongvibrations
DIAPHRAGM BREAKAGE NOT FOR MTP YA 65
ebreakageofoneormorediaphragmscancauseaggressiononthemechanicalpartofthepumpbythe
pumpedliquids.
efollowingaresymptomsofpossiblediaphragmbreakage:
• whitishcolouroftheoil(symptomofwaterinoil);
• excessiveoilconsumption;
• suddendisappearanceofoilfrompositive-displacementcompensator.
CAUTION
•Toavoidthenegativeconsequencesofsuchafault,useofthemachinemustbeimmediatelystoppedanda
Skilled Technician
mustbestraightawaycontacted(within24hours)tocarryoutthenecessaryinspections.
If,inthecaseofanevidentdiaphragmbreakage,a
Skilled Technician
cannotbecontactedstraightaway,it
isbesttoemptythemixofoilandpumpedliquidfromthepanandllitwithoilordieselfuel,toprevent
oxidisation.
•efollowingoencausediaphragmbreakage:
-blockagesinthesuctioncircuit(pipesofinadequatediameter,verydirtylter,pumpingofverydense
liquids,etc.);
-useofhighlyaggressivechemicalproducts.
EN