6
owner’s manual
Table 8-1a (Applicable to inverter air conditioner only)
16.1 Indoor Unit Error Display
Operation
lamp
Display
LED STATUS
1 time
E0
Indoor unit EEPROM error
2 times
E1
Communication malfunction between indoor and
outdoor units.
4 times
E3
Indoor fan speed has been out of control
5 times
E4
Indoor room temperature sensor T1 open circuit or short
circuit
6 times
E5
Evaporator coil temperature sensor T2 open circuit or
short circuit
7 times
EC
Refrigerant leakage detection
8 times
EE
Water-level alarm malfunction
1 time
F0
Current overload protection
2 times
F1
Open circuit or short circuit of outdoor ambient
temperature sensor T4
3 times
F2
Open circuit or short circuit of condenser coil
temperature sensor T3
4 times
F3
Open circuit or short circuit of Compressor discharge
temperature sensor T5
5 times
F4
Outdoor unit EEPROM error
6 times
F5
Outdoor fan speed has been out of control
7 times
F6
T2B sensor error
8 times
F7
Lifting-panel communication error
9 times
F8
Lifting-panel malfunction
10 times
F9
Lifting-panel is not closed
1 times
P0
IPM malfunction
2 times
P1
Over voltage or over low voltage protection
3 times
P2
High temperature protection of compressor top
4 times
P3
Outdoor low temperature protection
5 times
P4
Inverter compressor drive error
6 times
P5
Mode conflict
7 times
P6
Compressor low-pressure protection
8 times
P7
Outdoor IGBT temperature sensor error
Olight Xoff ☆(flash