CommScope FOSC-450D - Position the open block between the cables; Place the hook and loop fastener around the trays and basket, with the hook and loop fastener eye on top of the trays. Silicagel can be placed underneath; Slide the base over the Gel block and insert the frame into the base (check proper position); Insert the plugs in the unused ports. Remark: when installing the plugs be sure not to bend the crowns in the gel block

CommScope FOSC-450D
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
9 Closing the closure
9.1 Place the hook and loop fastener around the trays and basket,
with the hook and loop fastener eye on top of the trays. Silicagel can
be placed underneath.
9.2 Slide the base over the Gel block and insert the frame into the
base (check proper position).
8 Grounding
8.1 In case of grounding, mount grounding wire on the grouding
bolt.
B New termination plate
7.3 Position the open block between the cables.
9.3 Insert the plugs in the unused ports.
Remark: when installing the plugs be sure not to bend the crowns in the
gel block.
9.4 Tighten the trigger until it butts. If necessary, use wrench to
tighten the trigger.