Troubleshooting 7
October 2013 GB 51 /80
Display Possible Cause Remedy
A617:
Input 1
The programmable digital input 1
was activated, but is nevertheless
programmed as [free].
4)
Check the assignment of the
input in question.
4)
A618:
Input 2
The programmable digital input 2
was activated, but is nevertheless
programmed as [free].
4)
Check the assignment of the
input in question.
4)
A619:
Input 3
The programmable digital input 3
was activated, but is nevertheless
programmed as [free].
4)
Check the assignment of the
input in question.
4)
A620:
Input 4
The programmable digital input 4
was activated, but is nevertheless
programmed as [free].
4)
Check the assignment of the
input in question.
4)
A621:
Input 5
The programmable digital input 5
was activated, but is nevertheless
programmed as [free].
4)
Check the assignment of the
input in question.
4)
A622:
Input 6
The programmable digital input 6
was activated, but is nevertheless
programmed as [free].
4)
Check the assignment of the
input in question.
4)
A623:
SD-Card full
The SD card storage space is
used up.
Renew SD card. CompAir Part
No. ZS1067681
A624:
Water Filter
Differential pressure of the water
filter too high.
3)
Check, renew water filter if nec-
essary.
Error during level monitoring in discharge phase:
Solenoid valve for water outlet
faulty.
Check.
Dirt trap in front of solenoid valve
dirty.
Check dirt trap.
Outlet ball valve closed? Open ball valve.
A625:
Level control outlet
Faulty water level sensor B10. Check level sensor and wiring.
Error during level monitoring in intake phase:
Poor supply of water for machine,
water pressure may be too low.
Check water pressure.
Water treatment unit faulty. Check.
Solenoid valve for water inlet
faulty.
Check.
A626:
Level control supply
Faulty water level sensor B10. Check level sensor and wiring.
Error during water change in discharge phase:
Solenoid valve for water outlet
faulty.
Check.
Dirt trap in front of solenoid valve
dirty.
Check dirt trap.
Outlet ball valve closed? Open ball valve.
A627:
Water change drain
Faulty water level sensor B10. Check level sensor and wiring.
Chart 7-5: Warnings triggered from the compressor (A600 - A695)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CompAir DELCOS XL Series and is the answer not in the manual?

CompAir DELCOS XL Series Specifications

General IconGeneral
BrandCompAir
ModelDELCOS XL Series
CategoryController
LanguageEnglish

Related product manuals