3-16 Troubleshooting
Table 3-13
Pointing Device Interface Test Error Codes
Error
Code Description Recommended Action
8601-xx Mouse test failed The following steps apply to 8601-xx and 8603-xx:
1. Replace the top cover assembly.
8603-xx Interface test failed 2. Replace the system board and retest.
Table 3-14
CD-ROM Test Error Codes
Error
Code Description Recommended Action
3301-xx CD-ROM drive read test failed The following steps apply to error codes 3301-xx through
3305-xx and 6600-xx through 6623-xx:
3305-xx CD-ROM drive seek test failed 1. Replace the CD and retest.
6600-xx ID test failed 2. Replace the CD-ROM drive and retest.
6605-xx Read test failed 3. Replace the system board and retest.
6608-xx Controller test failed
6623-xx Random read test failed