EasyManua.ls Logo

Comprag F Series - Page 29

Comprag F Series
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29COMPRAG Screw air compressor F-Series
ALARM: 0110h
Maintenance interval exceeded
BELT SERV. SOON
ALARM: 0110h
Maintenance interval exceeded
AIR FILTER SOON
ALARM: 0110h
Maintenance interval exceeded
SEPARATOR SOON
ALARM: 0110h
Maintenance interval exceeded
OIL CHANGE SOON
ALARM: 0110h
Maintenance interval exceeded
GREASE M1 SOON
Alarms for maintenance are triggered at the set time before maintenance. The alarm message is dis-
played intermittently and repeatedly in the case of an overrun maintenance interval.
Restarting operation without eliminating the cause of the fault
isnot permitted!
Error messages (compressor stops or does not start)
TEMP: 99°C
Emergency stop pressed
EMERG. STOP C01
STOP: PRESSURE
Max. permissible working pressure of the compressor exceeded
HIGH 10.4bar
STOP:
Oil/air mixture temperature at the compressor outlet exceeded
TEMP HIGH 110°C
TEMP: 0°C
Drop below temperature (oil temperature below 5°C)
TEMPER LOW C01
STOP: OVERLOAD
Motor M1 permissible current consumption exceeded
M1 CUR. 104.8A

Related product manuals