Instruction
Booklet
For your safety
and continued
enjoyment of
this product,
always read the
instruction
booklet carefully
before using.
Model ITH94F
SERVICE CENTER
Conair Corporation
Service Department
7475 N. Glen Harbor Blvd.
Glendale, AZ 85307
For information on any Conair product, call
1-800-3-CONAIR or visit us on the web at
www.conair.com
Spanish translation is available on website
Please register this product at
www.conair.com/registration
©2021 Conair Corporation
Made in China
IB-17295A
21PA078771
DISPLAY INDICATORS
AND TROUBLESHOOTING
PRODUCT SPECIFICATIONSKEY TO SYMBOLS
Product name: Thermometer
Product No.: TE-82
Measurement
range: 89.6°F109.4°F (32.0°C–43.0°C)
Resolution: 0.1°F /0.1°C
Unit: °F C (default unit is °F)
Measurement
time: 1S
Operating
voltage: DC 3.0V
Low battery
parameters: 2.6±0.15V
Working current: <30mA
Standby current: <10uA
Working
environment: Temperature: 50˚F39˚F (10°C–40°C)
Relative humidity: ≤85% RH
Storage
environment: Temperature: -4˚F–131˚F (-20°C +55°C)
Relative humidity: <93% RH
Battery: 2 AAA
Expected
service life: Approximately 700 measurements
CLASSIFICATION
Internally powered equipment
Type BF applied part: Probe
IP22
Not category AP / APG equipment
Mode of operation: continuous operation
Measured temperature too low:
Displays “L when measured tempera-
ture is lower than 89.6ºF/32ºC
Measured temperature too high:
Displays “H” when measured tempera-
ture is higher than 109.4ºF/43ºC
Ambient temperature error: The
ambient temperature is either too high
(EH), too low (EL), or it is not stable (ErA)
due to significant temperature variations.
Ambient temperature must be within
50˚F-104˚F/10˚C-40˚C. Allow 30 minutes
for thermometer to reach room tem-
perature. Do not place thermometer
near fan, heater or AC unit.
Error function display: The ambient
temperature is not within the range of
50˚F-104˚F/10˚C-40˚C. Allow 30 minutes
for the ear thermometer to reach room
temperature and try again.
Blank display: Check that the
batteries have been loaded correctly.
Also check polarity of the batteries.
Low battery indication: If only the
battery icon is shown on the display
and it is flashing, the batteries should
be replaced immediately.
DISPLAY ERROR
WARNING indicates a hazardous situation
which, if not avoided, could result in death or
serious injury
CAUTION indicates a hazardous situation
which, if not avoided, may result in minor or
moderate injury
NOTICE addresses practices not related to
personal injuries, such as product and/or
property damage
Type BF
Do not dispose of this product in municipal
waste. Collection of such waste separately
for special treatment is necessary
Refer to instruction manual/booklet
Degree of protection against harmful ingress of
particulate matter and water
Manufacturer
Serial number
The package should be protected from rain
The package contains fragile products; please
handle with care
Transport package should be upright
The maximum stacking layers of the same
package; 5 means the layer limit
LIMITED THREE-YEAR WARRANTY
(U.S. AND CANADA ONLY)
Conair will repair or replace (at our option) your unit
free of charge for 36 months from the date of
purchase if the appliance is defective in
workmanship or materials.
To obtain service under this warranty, return the
defective product to the service center listed, together
with your purchase receipt. California residents need
only provide proof of purchase and should call
1-800-3-CONAIR for shipping instructions. In the
absence of a purchase receipt, the warranty period
shall be 36 months from the date of manufacture.
ANY IMPLIED WARRANTIES, OBLIGATIONS,
OR LIABILITIES, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, SHALL BE LIMITED
IN DURATION TO THE 36-MONTH DURATION
OF THIS WRITTEN, LIMITED WARRANTY.
Some states do not allow limitations on how
long an implied warranty lasts, so the above
limitations may not apply to you.
IN NO EVENT SHALL CONAIR BE LIABLE
FOR ANY SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES FOR BREACH
OF THIS OR ANY OTHER WARRANTY,
EXPRESS OR IMPLIED, WHATSOEVER.
Some states do not allow the exclusion or
limitation of special, incidental, or consequential
damages, so the above limitation may not apply
to you.
This warranty gives you specific legal rights, and you
may also have other rights, which vary from
state to state.
FCC MARKINGS:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV
technician for help.
CAUTION: Any changes or modifications not expressly
approved by Conair Corporation, the manufacturer of
this product and the party responsible for compliance,
could void the user’s authority to operate the equip-
ment. This thermometer is not a toy
.
SUPPLIER’S DECLARATION OF CONFORMITY
Brand: Conair
Model No.: ITH94F
Description: Infrared Ear Thermometer
Responsible Party: Conair Corporation,
1 Cummings Point Road, Stamford, CT 06902
203-351-9000
Standards: FCC Part 15 Subpart B, ANSI C63.4-2014
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) This device must accept any interference
received, including interference that may cause
undesired operation.
Date of issue: April 22, 2021
Shenzhen Belter Health Measurement and
Analysis Technology Co., Ltd.
702/704, Block C,
Tsinghua Unis Science
No.13 Langshan Rd.,
Hi-Tech Industrial Park (north).
Nanshan District, 518057 Shenzhen
People’s Republic of China
Belter model number TE-82
THERMOMETERTHERMOMETER
INFRARED EAR
ITH94F_IB-17295A.indd 2ITH94F_IB-17295A.indd 2 2021/5/24 10:04 AM2021/5/24 10:04 AM
Question and Answer IconNeed help?

Do you have a question about the Conair CARE ITH94F and is the answer not in the manual?

Summary

Introduction and Safety Warnings

Indications for Use

Explains the intended use of the infrared ear thermometer for monitoring body temperature.

Warnings and Precautions

Crucial safety warnings regarding misuse, health consultations, and fever interpretation.

General Cautions

Important cautions about device handling, cleaning, and environmental conditions.

Thermometer Operation and Functionality

How the Thermometer Works

Describes the infrared sensor technology and how it measures body temperature.

Getting to Know Your Thermometer

Identifies the main parts of the thermometer, including the sensor and display.

Setting Up Your Thermometer

Guides on turning on the device and ensuring proper battery installation for operation.

Selecting Fahrenheit or Celsius

Instructions on how to switch between Fahrenheit (°F) and Celsius (°C) measurement units.

Taking Temperature Readings

Before Taking a Temperature Reading

Preparation steps, including environmental adjustments and avoiding strenuous activity.

Measuring Ear Temperature

Detailed steps for inserting the probe and taking an accurate ear temperature reading.

Fever Alerts

Explains the different audible alerts for low-level and high-level fevers.

Device Management and Maintenance

Stored Reading Recall

Instructions on how to access and review previously stored temperature measurements.

Automatic Shutdown

Information about the device's power-saving automatic shutdown feature.

Battery Replacement

Instructions on how to safely replace the device's batteries when needed.

Battery Safety

Comprehensive safety guidelines for handling, storing, and disposing of batteries.

Cleaning and Maintenance

Procedures for cleaning the thermometer to ensure hygiene and accuracy.

Troubleshooting and Reference

Display Indicators and Troubleshooting

Explains display error codes and common troubleshooting steps for device issues.

Key to Symbols

Defines the meaning of various symbols found on the product and its packaging.

Product Specifications

Lists technical details like measurement range, resolution, voltage, and operating conditions.

Compliance and Warranty

Suppliers Declaration of Conformity

Formal declaration of the product's compliance with relevant standards and regulations.

FCC Markings

Information regarding compliance with FCC rules for radio frequency emissions.

Limited Three-Year Warranty

Details the warranty coverage, terms, and conditions for product repair or replacement.

Overview

The ConairCare Infrared Ear Thermometer (Model ITH94F) is a non-sterile, reusable, clinical electronic thermometer designed for monitoring human body temperature in people of all ages, suitable for both home and professional use. It utilizes an infrared sensor to detect energy radiated from the skin and tissue in the ear canal, providing stable and accurate measurements. The device has been cleared by the FDA and tested according to international medical device standards.

Function Description:

The primary function of the ITH94F is to measure body temperature via the ear canal. It detects infrared energy to provide a temperature reading, which is displayed on an LCD screen. The thermometer is equipped with a temperature alert system that beeps to indicate different levels of fever. A slower double beep signals a low-level fever (99.5°F - 101.3°F or 37.5°C - 38.5°C), while a faster triple beep indicates a high-grade fever (101.3°F/38.5°C or above). Temperatures between 96.4°F - 99.4°F (35.8°C - 37.4°C) are generally considered normal. The device also includes a memory function to recall previous readings and an automatic shutdown feature to conserve battery life.

Usage Features:

To use the thermometer, first ensure the sensor surface is clean. If visible dust or dirt is present, clean it with a cotton swab dipped in rubbing alcohol and allow the alcohol to evaporate before use. It is recommended to wait at least 30 seconds between measurements for accuracy. For babies, if drastic temperature changes are observed, wait a few minutes in the same environment until the baby's body temperature stabilizes. For babies between 3 months and 3 years of age, and for first-time users, it is recommended to take three temperature readings and reference the highest measurement.

Before taking a reading, ensure the thermometer is at room temperature (within 50°F-104°F/10°C-40°C) for at least 30 minutes, especially if it has been stored outside this range or near heat sources, fans, or AC units. Ear wax residue can lead to inaccurate readings, so it is advisable to clean the ear prior to use. Avoid strenuous exercise for at least 30 minutes before taking your temperature.

To turn on the device, press the power button. The screen will show segments, turn blue, and display the last measurement. When "000.0" appears and a beep is heard, the thermometer is ready. Remove the clear cap from the sensor probe. Straighten the ear canal by gently pulling the middle of the ear back and up. Place the probe firmly into the ear canal and press the SCAN/M button. A short beep will sound. Keep the probe in the ear until a longer beep signals the completion of the measurement. For consistent results, always take the temperature in the same ear and insert the device to a similar depth. Do not add a protective sleeve to the sensor, as this may affect accuracy.

The thermometer allows users to select between Fahrenheit (°F) and Celsius (°C) units. With the device off, press and hold the SCAN/M button for 5 seconds to display the current units. Press SCAN/M again to switch. The device will turn off after a few seconds.

The memory recall function allows users to view up to 32 previous readings. With the thermometer off, press the SCAN/M button. The memory icon (M in an oval) will flash. Press SCAN/M consecutively to scroll through stored readings. After viewing all, the display will return to the initial reading.

Maintenance Features:

The ITH94F is designed with precision parts and should not be dismantled, re-assembled, or modified. Avoid dropping the thermometer or subjecting it to strong impacts. If the sensor is broken, do not attempt to repair it; contact the customer service center.

For cleaning and maintenance, wipe the device with a soft, dry cloth after each use. If dirty, a damp cloth moistened with water or neutral detergent can be used, followed by a dry cloth. Avoid getting water into the thermometer body to prevent damage to internal electronic components. The thermometer features antibacterial plastic, proven to reduce surface bacteria. For additional contamination concerns, clean the thermometer with 75% alcohol before and after use, using only a small amount to avoid damaging electronics. Do not use volatile oil, paint thinner, or other chemical solvents.

The thermometer operates on 2 AAA alkaline batteries. When the battery icon flashes, it indicates low battery and replacement is needed. To replace, open the battery cover on the back of the handle, remove old batteries, and install new ones, ensuring correct polarity. Dispose of old batteries properly. If not used for more than 3 months, remove batteries to prevent damage from fluid leakage. Battery contacts should be clean before installation. Never recharge non-rechargeable batteries, mix old and new batteries, or put batteries into fire. Keep batteries away from children and seek medical help if ingested. Do not open, crush, puncture, or disassemble batteries. Dispose of batteries according to state and local regulations.

The device should be stored in a dry and dust-free environment, away from direct sunlight, ideally within a storage temperature range of 4°F to 131°F (-20°C to 55°C). Check the equipment casing for damage before each use; do not use if damaged. The sensor head is fragile and should be handled with care during cleaning. The device requires no calibration.

Conair CARE ITH94F Specifications

General IconGeneral
Measurement SiteForehead
Response Time1 second
DisplayLCD
Fever AlarmYes
TypeInfrared
Measurement Range32.0°C to 42.9°C (89.6°F to 109.2°F)
Auto Shut-offYes
Battery Type2 x AAA batteries
Fever IndicatorYes
Measurement Distance1-5 cm
Accuracy±0.2°C (±0.4°F)