Document No. 5-0324 Rev G
Page 11 of 21
CAUTION: ON BATTERIES WITH INTERNALLY THREADED
TERMINALS, USE AN OPEN END WRENCH ON THE FLAT PORTION
OF THE TERMINALS WHILE TORQUING THE TERMINAL BOLTS.
FAILURE TO DO SO MAY RESULT IN THE RUPTURE OF THE
BATTERY SEAL AT THE TERMINAL AND PREMATURE FAILURE OF
THE BATTERY.
CAUTION: USE ONLY THE HARDWARE PROVIDED WITH THE
BATTERY. DO NOT USE STAINLESS STEEL OR STEEL WASHERS
BETWEEN THE RING TERMINAL AND THE BATTERY TERMINAL.
13. Replace electrical compartment access panel.
14. Update aircraft weight and balance data, if necessary.
15. Perform an operational test.
16. Annotate battery log book with battery serial number, date of installation
and aircraft hours (see Appendix B).