18
Disposal
Dispose of the unserviceable device according to the applicable legal regulations.
Correcting Malfunctions
If the green LED is flashing this indicates that the device has found a very large met-
al object or that it is not correctly self-balanced. Wait 5 seconds until the device is
self-balanced again or turn the sensitivity regulator slowly clockwise to the right
towards "L” low until the flashing stops.
Technical Data
Power supply: 6.0 VDC 4* AA / Mignon 1,5V Alkaline-
batteries
Operating voltage: app. 4,7 to 6,5 VDC
Power consumption app. 20 mA
Battery lifetime: app. 50 hours continually
Depth of searching measured in air:
For a coin app. 15 to 20 cm
For a metal piece 10* 10 cm app. 35 to 40 cm
For a metal piece 50* 50 cm app. 70 to 80 cm
Diameter of searching coil 25 cm
Weight without batteries 1105 g
11
Table of Contents
Page
Introduction.............................................................................................................11
Prescribed Use .......................................................................................................12
Safety Instructions ..................................................................................................12
Scope of Delivery....................................................................................................14
Mounting.................................................................................................................14
Operational Control.................................................................................................15
Operation ................................................................................................................16
Battery Exchange....................................................................................................17
Disposal ..................................................................................................................18
Correcting Malfunctions..........................................................................................18
Technical Data ........................................................................................................18
Introduction
Dear customer,
we thank you for your acquiring this metal locator.
By acquiring this device you have purchased a product which has been designed
and manufactured according to the state of technical development today.
This product meets the requirements of the guideline 89/ 339/ EEC. Therefore, it sat-
isfies the standards of the established European and national guidelines. CE-confor-
mity has been proved; the relevant documents are in the manufacturer’s possession.
We kindly request the user to respect this operating manual to preserve this condi-
tion and to ensure safe operation.

Related product manuals