In
the
following
steps
you
will
start
with
low
IPA
output
power
and
with
zero
or
minimum
plate
voltage.
You
will
adjust
Grid
Tuning
and
Coupling
as
you
slowly
increase
drive
power
until
normal
drive
power
is
reached
and
then
you
will
slowly
increase
plate
voltage
while
adjusting
Grid
Tuning
and
Coupling
until
normal
operating
plate
voltage
is
reached.
Keep
the
IPA
Reflected
Power
to
a
minimum
as
you
make
adjustments
to
IPA
power
output
and
plate
voltage.
9.
Restore
primary
power
to
the
transmitter
and
turn
the
Filament
control
ON.
10.
Set
the
Exciter
Power
Output
Adjustment
fully
CCW.
11.
Press
the
Exciter
MUTE
Switch.
Turn
Plate
control
ON
and
reduce
the
plate
voltage
to
zero
or
to
minimum
with
the
Manual
Power
Control.
12.
Release
the
Exciter
MUTE
switch
and
slowly
increase
the
Exciter
output
while
watching
the
IPA
Reflected
Power.
Do
not
let
the
IPA
Reflected
power
exceed
60
watts.
13.
Adjust
the
PA
Grid
Tuning
and
Coupling
for
minimum
IPA
Reflected
Power
as
the
Exciter
output
is
increased
to
normal.
DO
NOT
EXCEED
20
AMPERES
ON
IPA
COLLECTOR
CURRENT.
The
normal
range
of
IPA
Collector
current
is
18
-
20
Amps.
14.
Slowly
increase
the
plate
voltage
with
the
Manual
Power
Control.
You
will
notice
that
the
IPA
Reflected
Power
will
increase
as
the
plate
voltage
is
increased.
Adjust
the
Grid
Tuning
and
Coupling
to
keep
the
IPA
Reflected
Power
at
minimum
as
the
plate
voltage
is
increased
toward
maximum.
15.
This
completes
the
adjustment
procedure.
Restore
the
transmitter
to
normal
configuration.
NOTE:
The
816R-2C,
3C,
4C,
and
5C
transmitters
do
not
use
the
150
watt
driver
and
the
normal
exciter
output
will
be
in
the
range
of
20
to
35
watts.
The
Exciter
RF
output
will
be
10
watts
if
the
IPA
power
output
is
controlled
by
the
collector
voltage
on
the
150
watt
Driver.
The
Driver
collector
voltage
and
the
IPA
output
is
set
by
adjustment
of
R40
on
the
IPA
Meter
Board.
The
Exciter
output
will
be
approximately
seven
watts
if
the
IPA
output
is
controlled
by
the
Exciter
RF
Output
Level
Control
only
and
the
transmiter
uses
the
150
driver
module.
Please
contact
Continental
Technical
Support
at
(214)
388-5800
if
you
have
questions
about
this
Information
Letter.
CONTINENTAL
ELECTRONICS
TECHNICAL
SUPPORT
PHONE
(214)388-5800
FAX
(214)381-7949
27