What to do if…
- 56 -
EN
?
The oven will operate if these errors occur
Error
Message
in the display
OES Steaming
Superheated
steam
Convection Regeneration
Cook &
Hold
Delta-T
E01 Not enough water X - -
up to
180°C
- X X
E02 Elec. temp. too high X X up to 140°C
up to
140°C
up to 140°C
up to
140°C
up to
140°C
E04
Electric fan
malfunction
X X up to 140°C
up to
140°C
up to 140°C
up to
140°C
up to
140°C
E11
Excessive oven
temperature
- - - - - - -
E15
Excessive
temperature of
condenser
X - -
up to
180°C
- X X
E33 Core temp. fault X X X X X X X
E36
Condenser sensor
failure
X X
2)
up to 180°C
2)
up to
180°C
2)
up to 180°C
2)
X
2)
X
2)
E 29
Sensor earth
connection
- - - - - - -
E80 ID error - - - - - - -
E81
Programme memory
error
X X X X X X X
E82
Working parameter
error
X X X X X X X
E83 Algo. error X X X X X X X
E89 I2C error X X X X X X X
X Operation possible
Operation not possible