Service manual OEB/OES/OGB/OGS
KD / 19.08.2009 5_00e_Troubleshooting list and error messages - Electronics_h.doc
Page 5 / 21
easy
touch
OEB
OES
OGB
OGS
Error
message
Error description Possible cause or remedy
Gas tap closed
Input undervoltage (< 195 V) (appliance connected
via cable reel)
OGS/OGB 10.20/12.20/20.20 (and 20.10 only SG)
starts poorly/does not start after glow electrode
replacement
- Wrong glow igniter fitted: short instead of long;
correct is 4018001 = long (wrong is 4018002 =
short)
STL has triggered (test passage)
Burner fan is not running (visual inspection or in
speed actual value in the service programmes)
Interruption in monitoring electrode wiring
E05.1
ID=52
No gas
B7.1 Safety temperature limiter for hot air has
triggered (test passage)
No gas at the burner HA1 (hot air1)
In addition same causes possible as with E05.0
E05.2
ID=54
No gas
B7.2 Safety temperature limiter for steam generator
has triggered (test passage)
No gas at the burner SG (steam generator)
In addition same causes possible as with E05.0
E05.3
ID=53
No gas
No gas at the burner HA2 (hot air2)
In addition same causes possible as with E05.0
E05.4-1
ID=52
No gas
Start speed at the burner HA1 not reached
PWM signal interrupted
E05.4-2
ID=52
No gas
Start speed at the burner HA1 not reached
Possibly voltage supply disturbed
E05.5-1
ID=54
No gas
Start speed at the burner SG not reached
PWM signal interrupted
E05.5-2
ID=54
No gas
Start speed at the burner SG not reached
Possibly voltage supply disturbed
E05.6-1
ID=53
No gas
(only 20.10 / 20.20)
Start speed at the burner HA2 not reached
PWM signal interrupted
E05.6-2
ID=53
No gas
(only 20.10 / 20.20)
Start speed at the burner HA2 not reached
Possibly voltage supply disturbed
E05.7-1
No gas
Full load speed at the burner HA1 not reached
PWM signal interrupted
E05.7-2
No gas
Full load speed at the burner HA1 not reached
Possibly voltage supply disturbed
E05.8-1
No gas
Full load speed at the burner SG not reached
PWM signal interrupted