Service manual OEB/OES/OGB/OGS
KD / 19.08.2009 5_00e_Troubleshooting list and error messages - Electronics_h.doc
Page 9 / 21
easy
touch
OEB
OES
OGB
OGS
Error
message
Error description Possible cause or remedy
c) Thermoelement defective.
E29.2
ID=16
CTS2 short circuit to
earth
• Thermoelement sensor B10 has contact with
appliance housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.3
ID=17
CTS3 short circuit to
earth
• Thermoelement sensor B10 has contact with
appliance housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.4
ID=18
CTS4 short circuit to
earth
• Thermoelement sensor B10 has contact with
appliance housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E33.0 Steam generator
operating fault (No
temperature increase
in the SG within
3 mins. by >5°C on
the B3 sensor)
• Immersion heater defective
• Heater contactor defective
• Calcified B3 sensor
E34.0 SG pump error
Pump does not start
(double level sensor
does not reach
lower level within 20
secs.)
• Pump defective (M4)
• Pump blocked / contaminated
• Water level sensor has short circuit to earth due to
calcification
• Filling gap of the area touching the water is calcified
together with the double level sensor
E80.0 ID error (identity
error)
• It cannot be determined whether the appliance is gas
or electric, therefore all outputs are switched off.
• IDM module defective
E81.0 Programme memory
error
• If the working parameters of a multi-step
programme are not between min. and max. values
• After saving a cooking plan in the cookbook the
temperature display is changed from °C to
°Fahrenheit
E82.0 WP error
(working parameter
error)
• If the working parameters of a cooking programme
are not between min. and max. values
• Invalid data stored in the cookbook
E83.0 Alg. error (invalid
cooking algorithm)
• Incompatible software between operating module
and control module