EasyManua.ls Logo

CONWIN Dual Split-Second Sizer - Page 2

Default Icon
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
On/Off
LED Mode Indicator
1
2
3
4
Select and set the proper mode by
pressing the mode setting button.
The LED display will indicate which
mode the D ual Split-Second Sizer is
in. (See Chart Below)
Setting the Dual Split-Second Size r
Mode Settings
LED wil l light to indicate which mode
the Dual Split-Second Sizer is set to.
(see photo #2)
Place the balloon over the inflat ing
outlet. Slightly roll the neck of the
balloo n over the inflating tip. This
will insure the gas enters t he center
of t he balloon and the round
shape
of the balloon is maintained during
the inflation process.
Tap the foot pedal to begin the
inflation cycle. When the system
automatically shuts-off, remove the
balloons from the outlets without
allowing any of the gas t o escape.
Reference the size setting chart below and
set the Dual Split-Second Sizer to the
appropriate time and pressure settings. To
adjust the inlet pressure, pull the knob up to
release it and turn it clockwise to increase
the pressure and speed of in
flation. This will
increase the size of the balloon. To decrease
the size of the balloon and speed of
inflation, turn the knob counter-clockwise.
Press the knob down to lock it in place after
making the desired setting.
2
6.6 Seconds
6.9 Seconds
80 PSI 80 PSI
14”
16”
Dual Split-Second Sizer Settings Chart
BALLOON
S IZE
4.2 Seconds
4.4 Seconds
80 PSI
80 PSI
60/40 HELIUM/AIR OUTLET
1 Outlet 2 Outlets
60/40 Helium/Air Outlet Settings
The following settings should be used as guidelines for the using
the optional 60/40 Helium/Air Outlet with the Dual Split-Second
Sizer. The 60/40 Helium/Air Outlet is recommended for use with
14” or larger balloons. (See back page for details).
BALLOON
SIZE
5”
N/A N/A
N/A N/A
0.6 Seconds 0.8 Seconds
70 PSI 70 PSI
1.1 Seconds 1.4 Seconds
70 PSI 70 PSI
2.0 Seconds 2.7 Seconds
70 PSI 70 PSI
3.2 Seconds 4.1 Seconds
70 PSI 70 PSI
0.2 Seconds 0.3 Seconds
90 PSI 75 PSI
1.5 Seconds 1.9 Seconds
75 PSI 75 PSI
2.8 Seconds 3.7 Seconds
75 PSI 75 PSI
5.2 Seconds 6.5 Seconds
75 PSI 75 PSI
8.3 Seconds 9.9 Seconds
75 PSI 90 P SI
0.3 Seconds 0.5 Seconds
75 PSI 75 PSI
1.9 Seconds 3.1 Seconds
75 PSI 75 PSI
3.4 Seconds 5.5 Seconds
75 PSI 75 PSI
6.3 Seconds 9.9 Se
conds
90 PSI 90 PSI
N/A N/A
N/A N/A
9”
11”
14”
16”
HELIUM
1 Outlet 2 Outlets
1 Outlet 2 Outlets
NITROGEN
1 Outlet 2 Outlets
AIR COMPRESSOR
The followin g settings should be u sed as guidelines for th e Dual Split-Second Sizer. Please note that size settings will vary based on user preference, balloon color
and manufacturer. To adjust the size of balloon to your individual preference it is necess ary to i nflate test balloons. PSI SETTINGS refer t o the gauge located on
adjustable regulator at the back of Dual Split-Second Sizer. This controls the speed of the inflation cycle. SECONDS SETTINGS refers to the tenth o
f a second
increment readouts on digital display(s) on Dual Split-Second Sizer.
Important: To ensure consistent balloon sizing when using helium or nitrogen, it is necessary t o check the size of the balloons every 1/3 of a cylinder of
gas. If necessary, increase the size of the balloon by eithe r increasing the size setting or the inlet pressure.
MODE 1
Use Mode 1 to inflate t wo
balloo ns to the same size.
Timer A
Timer B
Left Outlet
Right Outlet
ON
OFF
ON
ON
MODE 2
Use Mode 2 to inflate one balloon
or when using an acce ssory outlet.
Timer A
Timer B
Left Outlet
Right Outlet
MODE 3
Use Mode 3 to inflate two
balloons to different sizes.
Timer A
Timer B
Left Outlet
Right Outlet
ON
OFF
ON
OFF
ON
ON
ON
ON