3. Testing Commands
Page 70 497096, Issue 6
Printing the Event Log (9853 only)
Note: 975x models do not have the connector required for event log printing.
To print the event log, make sure the system is in installer mode, and then
press 90y0. To stop printing, press X.
To toggle the logging printer on and off, press 90y7. The keypad gives a
Chime tone when the printer is turned on and a "beep beep" confirmation tone
when the printer is turned off. This is a test mode and is cancelled if power is
lost. Use Command 180 to turn printing on indefinitely.
Figure 2 shows a sample of a printed log.
– 9853 -
14/12/01 18:42:30 Sounder Tamper
<END OF LOG>
Figure 2. Sample Log Print
To print a listing of the control unit's configuration, press 908y
Note: The log is protected and cannot be erased by the Installer or a user.
Event Log Messages
* Printed event messages start with a time and date stamp.
Keypad Display Printed (9853 only)* Meaning
AC Alert Keypad displayed mains fail message
AC Fail AC Lost Mains power supply failed
AC Restore AC Restore Mains power supply restored
Al Conf Dis K== Al Conf Dis K== Alarm confirmation disabled by lock
switch
Al Confirm Z== Confirmed Z== Confirmed alarm on zone ==
Alarm Abort U== Alarm Abort User aborted alarm
AntiMask Al Z== Anti Mask Alarm Z== Anti-mask alarm on zone ==
AntiMask Rs Z== Anti Mask Restore Z== Anti-mask alarm on zone == reset
AntiMask Tp Z== Anti Mask Tamp. Z== Tamper on anti-mask zone ==
ATE L.F. All ATE L.F. All Alarm Transmission Equipment: fault on
all lines
ATE L.F. Rstr ATE L.F. Rstr Alarm Transmission Equipment: line
fault(s) restored
ATE L.F. Single ATE L.F. Single Alarm Transmission Equipment: fault on
one line
AUX DC Fail AUX Trouble Auxiliary power failed
AUX DC Fail Rstr AUX Restore Auxiliary power restored
Bad Checksum EEPROM Failure Control unit memory corrupted
Batt Flt Rstr Battery Restored Battery reconnected
Batt Load Fail Batt Load Test Fail Battery failed load test
Batt Missing Battery Missing Battery disconnected

Table of Contents

Other manuals for Cooper Scantronic 9 5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cooper Scantronic 9 5 Series and is the answer not in the manual?

Cooper Scantronic 9 5 Series Specifications

General IconGeneral
BrandCooper
ModelScantronic 9 5 Series
CategoryControl Unit
LanguageEnglish

Related product manuals