Remote Configuring
After charging the remote fully, proceed with the setup
by following these steps:
1) Remove endcap and slide the power switch right to the “off” position.
2) Plug in the provided mini-USB cable to the remote USB port located on
the left side behind the endcap (see figure one for location).
3) Plug the other end of the USB cable into a computer or chassis
with compatible software already installed and running.
4) Slide the power switch left to the “on” position.
5) Enter the password requested on the HR200 screen using
the following numeric buttons in this sequence: 3526 enter.
6) You are now ready to proceed with configuration.
Please refer to the HR200 integration note or your System Training Guide
for more details.
Removal and Replacement of the battery
1) To access the battery locate the Endcap Release Button on the bottom of
the remote. While depressing the Endcap release button pull the Endcap away
from the body of the remote as illustrated.
2) Remove the two screws holding the Battery Retaining Bracket in place
using a #1 Phillips Screwdriver. Slide out the old battery.
3) CAUTION: Danger of explosion if battery is incorrectly replaced.
Replace battery with only Core Brands approved battery part number 2900008.
(Contact your local dealer for replacement battery.)
4) Assure proper orientation while inserting replacement battery.
Battery label should be faced down and gold plated charging contacts
should enter the unit first. Refer to the illustration above. Improper installation
of the battery will result in permanent damage to the remote.
HR200
Quick Reference Guide
English
© 2014 Core Brands, LLC, aNortek company.
P/N 9901357 Rev. A 07/2014
3 4
on rear
on rear