Installation and Service Manual
Publication Number: 710160089 - 6 - © 2004, IMI Cornelius Inc.
ICE BANK CONTROL REPLACEMENT
1. Disconnect power to dispenser.
2. Remove cap from drain tube and position the drain tube in the drain pan and drain the water bath.
3. Refill water bath with warm water at a temperature of 120
o
F (49
o
C). Let stand for ten (10) minutes
to melt ice bank. If ice remains, repeat Steps 2 and 3 until all ice is melted. Failure to melt all ice
may cause the dispenser to freeze-up after the new ice bank control is installed.
4. Remove two screws from dispenser top and remove top.
5. Remove old ice bank control.
6. Install new ice bank control by pushing probe down into the 3/4” tube until it stops on the bottom of
the tube. Secure probe with tape.
7. Fill water bath with fresh water. Replace dispenser top and secure with two screws.
8. Connect dispenser to power source and turn ON.