Do you have a question about the Cornell Romany and is the answer not in the manual?
Details on replacing pre-amp and power valves, specifying types for Romany and Romany Plus models.
Safety precautions for valve replacement, handling hot valves, and general amplifier safety.
Details on the guitar input jack and the volume control for gain and overall level.
Explanation of EQ Cut, Treble, Bass, and Output controls, including the output jack.
Description of the mains indicator, mains fuse, and HT fuse for amplifier protection.
Specifies power requirements (115V/230V) and fuse ratings for mains and HT.
Details input impedance, output power, cabinet construction, dimensions, and weight.
Lists available options such as cabinet colours and specific speaker configurations.
| voltage | 115 Volts AC |
|---|---|
| frequency | 60Hz |
| power consumption | 50 Watts |
| speaker type | Jensen CH 10/70 |
|---|---|
| impedance | 16 Ohm |
| height | 13 in |
|---|---|
| width | 18 in |
| depth | 7¾ in |
| weight | 25.3 lbs |
| voltage | 230 Volts AC |
|---|---|
| frequency | 50Hz |
| power consumption | 50 Watts |
| speaker type | Jensen CH 112/70 |
|---|---|
| impedance | 8 Ohm |
| height | 15 in |
|---|---|
| width | 21 in |
| depth | 8½ in |
| weight | 29 lbs |