8
ENGLISH
Function and safety checks
1. Disconnect the compressed air from the nail gun.
2. Remove any nails from the magazine.
3. Make sure that the safety lock move freely up and down by pressing
the tool against a work surface.
4. Connect to the compressed air.
5. Press the tool against the work surface. The tool must not fire.
6. Take the tool away from the work surface, and make sure the safety lock returns
to its position. Press the trigger in. The tool must not fire.
7. Press the tool against the work surface, press the trigger. The tool should fire.
Loading
1. Open the magazine by pressing the lock down and pulling it straight out.
2. Place nails in the magazine, ensure
that the tips point downward, and lie
against the bottom of the magazine.
3. Shove the magazine back until the
magazine lock clicks firmly in place.