28
27
WATER FLOW DIAGRAM / PERFORMANCE DATA SHEET
|
CHPI-620L
Others
Water Filtration System Performance Data Sheet
Model: CHPI-620L
This system has been tested and certied by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specied in NSF/ANSI 42, 53, and 58.
Substance
Inuent Challenge Concentration
(mg/L unless specied)
Maximum Allowable Product Water
Concentration
(mg/L unless specied)
Percent Reduction
(%)
Arsenic (Pentavalent) 0.050 ± 10% 0.010 97.8
Barium 10.0 ± 10% 2.0 97.2
Radium 226/228 25 pCi/L 5 pCi/L 80
Cadmium 0.03 ± 10% 0.005 98.2
Chromium (Hexavalent) 0.3 ± 10% 0.1 98.6
Chromium (Trivalent) 0.3 ± 10% 0.1 99.4
Lead 0.15 ± 10% 0.010 99.1
Copper 3.0 ± 10% 1.3 98.1
Selenium 0.10 ± 10% 0.05 98.3
TDS 750 ± 40 187 92.6
Aesthetic Chlorine 2.0 ± 10% ≥ 50% reduction 79.3
VOC* 0.300 ± 10% ≥ 95% reduction 99.6
While testing was performed under laboratory conditions, actual performance may vary.
General Operating Information:
Rated Capacity
1 100 L (for VOC)
19 000 L (for Aesthetic Chlorine)
Min-Max operating pressure: 138 kPa ~ 827 kPa
Min-Max feed water temperature: 5 ºC ~ 35 ºC
Rated Service Flow 0.26 L/min
Daily Water Production Rate 258.2 L/d
Product Eciency Rating 47.1 %
Electrical Requirements: 120 V~ 60 Hz
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
• Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user
responsibility, and parts and service availability.
• The inuent water to the system shall include the following characteristics:
o No organic solvents
o Chlorine: < 2 mg/L
o pH: 7 - 8
o Temperature: 5 ºC ~ 35 ºC
o Iron: < 2 mg/L
o Turbidity: < 1 NTU
o Hardness: < 1 000 mg/L