WATER FLOW DIAGRAM / PERFORMANCE DATA SHEET
|
CHPI-620L
Others
Water Filtration System Performance Data Sheet
Model: CHPI-620L
This system has been tested and certied by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specied in NSF/ANSI 42, 53, and 58.
Substance
Inuent Challenge Concentration
(mg/L unless specied)
Maximum Allowable Product Water
Concentration
(mg/L unless specied)
Percent Reduction
(%)
Arsenic (Pentavalent) 0.050 ± 10% 0.010 97.8
Barium 10.0 ± 10% 2.0 97.2
Radium 226/228 25 pCi/L 5 pCi/L 80
Cadmium 0.03 ± 10% 0.005 98.2
Chromium (Hexavalent) 0.3 ± 10% 0.1 98.6
Chromium (Trivalent) 0.3 ± 10% 0.1 99.4
Lead 0.15 ± 10% 0.010 99.1
Copper 3.0 ± 10% 1.3 98.1
Selenium 0.10 ± 10% 0.05 98.3
TDS 750 ± 40 187 92.6
Aesthetic Chlorine 2.0 ± 10% ≥ 50% reduction 79.3
VOC* 0.300 ± 10% ≥ 95% reduction 99.6
While testing was performed under laboratory conditions, actual performance may vary.
General Operating Information:
Rated Capacity
1 100 L (for VOC)
19 000 L (for Aesthetic Chlorine)
Min-Max operating pressure: 138 kPa ~ 827 kPa
Min-Max feed water temperature: 5 ºC ~ 35 ºC
Rated Service Flow 0.26 L/min
Daily Water Production Rate 258.2 L/d
Product Eciency Rating 47.1 %
Electrical Requirements: 120 V~ 60 Hz
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
Refer to the owners manual for specific installation instructions, manufacturers limited warranty, user
responsibility, and parts and service availability.
The inuent water to the system shall include the following characteristics:
o No organic solvents
o Chlorine: < 2 mg/L
o pH: 7 - 8
o Temperature: 5 ºC ~ 35 ºC
o Iron: < 2 mg/L
o Turbidity: < 1 NTU
o Hardness: < 1 000 mg/L

Other manuals for Coway CHPI-620L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Coway CHPI-620L and is the answer not in the manual?

Coway CHPI-620L Specifications

General IconGeneral
BrandCoway
ModelCHPI-620L
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals