Guide to installing the Cozy 12 and Cozy 18 sauna stoves
Before installaon
1.The rst heang of the stove is advisable to do outdoors without heater stones before installaon, as
the heat-resistant paint of the outer shell of the stove reaches its nal hardness only aer the rst
heang and can emit an unpleasant smell. If necessary, to achieve dra, connect the smoke pipe to the
stove’s chimney pipe end.
Before installing the stove, make sure that all safety distance requirements are met. Electrical
equipment, cables or #ammable materials may not be located around the stove within the ranges
described by the requirements. The safety requirements of the chimney pipe must also be taken into
account when installing!
• When installing the stove, all relevant local and EU standards must be followed. The stove is suitable
for use in the case of a common smoke #ue for several hearths if the necessary requirements for the
operaon of the heater are ensured. The joint #ue chimney must be designed and constructed taking
into account the technical condions and possible simultaneous operaon of all heang devices
connected to the common #ue.
• More detailed informaon on re safety regulaons can be obtained from local representaves of
agencies responsible for re safety and exercising appropriate supervision.
• The stove must be installed in such a way as to ensure access for cleaning the smoke pipe and chimney
#ue.
2. Protecng the oor
NB! The Cozy sauna stove is suitable for installing only on a #oor made of non-combusble heat-tolerant
material or on other protected material.
A. Concrete #oor without les. If the concrete layer is at least 60 mm thick, then the stove can be placed
directly on the concrete without addional safety measures. Make sure there are no electrical cables or
water pipes in the concrete under the stove.
B. Tile #oor and #ammable #oor. Plate mixes and mortars and waterproof materials used under the
plates cannot withstand the thermal radiaon of the stove. Protect the #oor with a stone or thermally
insulated metal plate. If the #oor in front of the stove is made of #ammable material, a non-combusble
#oor protecon must be installed. The #oor on which the stove is placed must withstand the pressure
generated by the legs of the heater, along with stones and chimney. If the exisng #oor cannot withstand
the weight of the stove, addional equipment must be used - for example, a load-distribung plate.
3. Safety distances from ammable materials
Safety distances apply to stoves lled with heater stones.
- Ceiling. Minimum safety distance from the surface of the heater stones to the ceiling is 1340mm
- Walls, seats, doors, railings and sauna bench made of #ammable materials. The minimum safety
distance from #ammable materials is: