2
16019 Malfunction catalog
一. Malfunction List
Common Trouble and processing Methods are listed as follow:
Error
NO
Phenomenon Description Processing Methods
01 No Function
When Starting.
The Controller`s LCD Nodisplay:
Fuse melts (in the Power Source Box or on the
main PCB).
Power supply circuit poorly connected.
EMC Board fails.
Main PCB fails.
Replace Fuse
Replace Power Box.
Replace EMC Board.
Replace main PCB.
02 No Function
When Starting.
The Controller`s LCD Display:
Mechanical switch fails or it’s wire is opened.
Up or Down Stroke Photo-electricity fails.
Main PCB fails.
Kneading is on without pressing any key when
starting and no response by pressing other keys.
Replace mechanical switch or
it's wire.
Replace Stroke Photo-
electricity.
Replace the main PCB.
Width Inspection Board of PCB
fails, replace it.
03 No Width
switchover.
The terminals of Width Inspection on main PCB
and wires are poorly connected.
The terminals of Width Inspection on massage
mechanical and wires are poorly connected.
Width Inspection fails.
Main PCB fails.
&Plug the terminal securely
or replace the wires.
Replace Width Inspection.
Replace the main PCB.