16019 Malfunction catalog
一. Malfunction List
Common Trouble and processing Methods are listed as follow:
Error
NO
Phenomenon Description Processing Methods
01 No Function
When Starting.
The Controller`s LCD Nodisplay:
① Fuse melts (in the Power Source Box or on the
main PCB).
② Power supply circuit poorly connected.
③ EMC Board fails.
④ Main PCB fails.
①Replace Fuse
②Replace Power Box.
③Replace EMC Board.
④Replace main PCB.
02 No Function
When Starting.
The Controller`s LCD Display:
① Mechanical switch fails or it’s wire is opened.
② Up or Down Stroke Photo-electricity fails.
③ Main PCB fails.
④Kneading is on without pressing any key when
starting and no response by pressing other keys.
①Replace mechanical switch or
it's wire.
②Replace Stroke Photo-
electricity.
③Replace the main PCB.
④Width Inspection Board of PCB
fails, replace it.
03 No Width
switchover.
① The terminals of Width Inspection on main PCB
and wires are poorly connected.
②The terminals of Width Inspection on massage
mechanical and wires are poorly connected.
③Width Inspection fails.
④Main PCB fails.
①&②Plug the terminal securely
or replace the wires.
③Replace Width Inspection.
④Replace the main PCB.