Problem Solution
Unit Will Not Turn On The pump is not making any noise when switch is turned on.
o Check to make sure battery is charged.
o Check in-line fuses on wiring harness
o Replace if needed.
o Check to make sure electrical connections are secure
o If these steps do not generate results please contact
customer service 1-800-345-2231.
Pump is running but no water flow.
o Check lines for pinches or kinks.
o Remove and clean filter, tighten cap.
o Open two valves to allow air to escape.
o If there is still no water pressure please contact
customer service to order replacement parts.
Leaking Valves Check threads at connections for cracks caused by over-
tightening. If no cracks make sure that all connections are
tight (hand tight) and try the unit again.
Leaking Manifold If a leak is on a threaded part, tighten the fitting finger tight.
Check for cracks in the fittings and around the hose
connections.
If a leak is between the glued parts, contact customer service.
Flat Tire Air up tire ( do not exceed 30 PSI). If significant pressure loss
occurs within 24 hours check for punctures or cracks.
If under warranty contact customer service for warranty repair.
Pump Back Plate
Broken