Combi
2.8.3 Service Menu
- Located on the right side of menu number 4.
- The menu is selected by clicking the button number 8.
- It is possible to navigate between the settings shown below in the menu by
using the number 8 button.
- When the desired setting is reached, it can be selected by clicking the 8 button.
- While in the selected setting, the selected setting is brought to the desired
value by swiping left and right with the 8 button.
- Exit back with the button number 9.
Calibration of the room temperature sensor of the heater (OFFSET)
The room temperature sensor of the connected heater can be adapted to the
installation situation of the sensor. Adjustment can be made in 0.5 °C steps in the
range of 5 °C to -5 °C.
Sample:
Set room temperature 23 °C OFFSET= -1 °C
Nominal value for heating = 22 °C
Standard setting: 0 °C (Celsius). °C / °F temperature display
Selection of °C (Celsius) or °F (Fahrenheit) temperature display.
Standart setting: °C (Celsius).
Changing the backlight
Changing the backlighting of the Truma CP plus VarioHeat control unit in 10
steps.
12 hour / 24 hour mode
Display of time in 12 hour (a.m., p.m.) / 24 hour mode.
54